TRYPTON series basic pack includes:

• Prefiltration system of 20 and 5 microns(µm)
• Inlet and permeate water flowmeter
• High pressure regulating valve
• High and low pressure switches & gauges
• Conductivity meter sensor
• Control panel with the system´s key parameters

See optional accessories to  customize your system

MODEL

TRYPTON 2

TRYPTON 4

TRYPTON 6

Nominal flow (m3/day) 25ºC - 35.000 ppm

2

4

6

Feed water flow  (m3/h)

0,69

Minimum feed water pressure  (bar)

3

3

3

Operational system pressure  (bar)

51

51,5

51

Maximum system pressure (bar)

69

69

69

Maximum permeate back-pressure (bar)

2

2

2

Power consumption (kW)

1,25

1,29

1,25

Effciency(kWh/m3)

14,04

7,76

5,10

Average Recovery (%)

12,9

23,33

35,51

Nominal product conductivity (mS/m)

≤ 75 mS/m

≤ 75 mS/m

≤ 75 mS/m

Maximum product conductivity  (mS/m)

≤ 100 mS/m

≤ 100 mS/m

≤ 100 mS/m

Membranes Number

1

2

3

Membranes Type

2540

2540

2540

Product water connection

1/2 ? BSP

1/2 ? BSP

1/2 ? BSP

Concentrate connection

1/2 ? BSP

1/2 ? BSP

1/2 ? BSP

Feed water connection

3/4? BSP

3/4? BSP

3/4? BSP

Unit dimension (m) (LxWxH)

1,15x0,60x0,90

Unit dry weight  (kg)

55

65

75

 

Descripción: f0644360.tif

THESEUS series basic pack includes:

• Inlet and permeate water flowmeter
• High pressure regulating valve
• High and low pressure switches & gauges
• Conductivity meter sensor
• Control panel with the system´s key parameters

See optional accessories to  customize your system


MODEL

THESEUS 10

THESEUS 13

THESEUS 15

Nominal flow (m3/day) 25ºC - 35.000 ppm

10

13

15

Feed water flow  (m3/h)

1,38

Minimum feed water pressure  (bar)

3

3

3

Operational system pressure  (bar)

56

61

62

Maximum system pressure (bar)

69

69

69

Maximum permeate back-pressure (bar)

2

2

2

Power consumption (kW)

2,72

2,99

3,0

Effciency(kWh/m3)

6,63

5,29

4,6

Average Recovery (%)

29,7

41

47,8

Nominal product conductivity (mS/m)

≤ 75 mS/m

≤ 75 mS/m

≤ 75 mS/m

Maximum product conductivity  (mS/m)

≤ 100 mS/m

≤ 100 mS/m

≤ 100 mS/m

Membranes Number

2

3

4

Membranes Type

4040

4040

4040

Product water connection

1/2 ? BSP

1/2 ? BSP

1/2 ? BSP

Concentrate connection

1/2 ? BSP

1/2 ? BSP

1/2 ? BSP

Feed water connection

3/4? BSP

3/4? BSP

3/4? BSP

Unit dimension (m) (LxWxH)

1.27x1,12x0,50

Unit dry weight  (kg)

65

75

85

 

TEKNIWAT     series     basic     pack includes:

• 25 & 5 µm PP micro filtration
• Automatic back flushing
• Control panel with the system´s key parameters
• Membrane and horizontal or vertical pressure vessels module.
• High pressure pump & high efficiency motor.

See optional accessories to  customize your system

MODEL

TEKNIWAT

22

TEKNIWAT

28

TEKNIWAT

40

TEKNIWAT

55

Nominal flow (m3/day) 25ºC - 35.000 ppm

22

28

40

55

Feed water flow  (m3/h)

4,08

5,70

Minimum feed water pressure  (bar)

3

3

3

3

Operational system pressure  (bar)

49

45

47,5

59,2

Maximum system pressure (bar)

69

69

69

69

Maximum permeate back-pressure (bar)

2

2

2

2

Power consumption (kW)

7,1

6,42

9,61

11,98

Effciency(kWh/m3)

7,9

5,49

5,6

5,3

Average Recovery (%)

22

28,7

28,7

39,46

Nominal product conductivity (mS/m)

≤ 75 mS/m

≤ 75 mS/m

≤ 75 mS/m

≤ 75 mS/m

Maximum product conductivity  (mS/m)

≤ 100 mS/m

≤ 100 mS/m

≤ 100 mS/m

≤ 100 mS/m

Membranes Number

1

2

2

3

Membranes Type

8040

8040

8040

8040

Product water connection

3/4? BSP

3/4? BSP

3/4? BSP

3/4? BSP

Concentrate connection

3/4? BSP

3/4? BSP

3/4? BSP

3/4? BSP

Feed water connection

1 1/4? BSP

1 1/4? BSP

1 1/4? BSP

1 1/4? BSP

Unit dimension (m) (LxWxH)

max. 1,50x1,40x1,00

Unit dry weight  (kg)

410

430

450

495







 

POSEIDON series basic pack includes:

• 60 µm hydrocyclone filter disc
• Automatic back flushing
• Control panel with the system´s key parameters
• Membrane and horizontal or vertical pressure vessels module.
• High pressure pump & high efficiency motor.

See optional accessories to  customize your system

MODEL

POSEIDON

 65

POSEIDON  

80

POSEIDON

100

POSEIDON

150

Nominal flow (m3/day) 25ºC - 35.000 ppm

65

80

100

150

Feed water flow  (m3/h)

5,70

8

10

13,5

Minimum feed water pressure  (bar)

3

3

3

3

Operational system pressure  (bar)

59,2

52,4

57,5

56,6

Maximum system pressure (bar)

69

69

69

69

Maximum permeate back-pressure (bar)

2

2

2

2

Power consumption (kW)

11,98

15,2

24.2

30

Effciency(kWh/m3)

5,3

4,9

5,1

4,52

Average Recovery (%)

39,46

33,7

40,5

45,5

Nominal product conductivity (mS/m)

≤ 75 mS/m

≤ 75 mS/m

≤ 75 mS/m

≤ 75 mS/m

Maximum product conductivity  (mS/m)

≤ 100 mS/m

≤ 100 mS/m

≤ 100 mS/m

≤ 100 mS/m

Membranes Number

4

4

5

8

Membranes Type

8040

8040

8040

8040

Product water connection

1? BSP

1? BSP

1? BSP

1 1/2? BSP

Concentrate connection

1? BSP

1? BSP

1? BSP

1 1/2? BSP

Feed water connection

1 1/2? BSP

1 1/2? BSP

1 1/2? BSP

2? BSP

Unit dimension (m) (LxWxH)

1,6x1,4x1,7

1,6x1,5x1,8

2,0x1,5x1,8

2,6x1,5x1,8

Unit dry weight  (kg)

560

710

1150

1750

 

 